How To Fix An ASUS Laptop Touchscreen Not Working (2026)

A touchscreen on an ASUS laptop can stop responding, respond in the wrong place or react too easily.

ASUS has one article for touchscreen and touch panel problems on Windows 11 and Windows 10, and the steps are nearly the same for both.

This guide follows that article in order, with the Windows 11 menu names first.

Quick answer: match the symptom

SymptomWhat ASUS says to try
Touch does nothing at allCheck that the laptop has a touchscreen, then enable and reinstall the touch driver.
Touch is inaccurate or lands in the wrong spotRecalibrate the touch display in Control Panel.
Screen reacts too easily or erraticallyClean the screen and remove any protector or accessory.
Calibration made it worseReset the touch calibration.
Started after a recent changeUse System Restore.

The steps in ASUS order

ASUS says to use the steps in order if the touchscreen is inaccurate, unresponsive or too sensitive.

StepWindows 11Windows 10
1Confirm touch supportConfirm touch support
2Clean the LCDClean the LCD
3Enable and reinstall the touch driverEnable and reinstall the touch driver
4Update BIOS, Windows and driversUpdate BIOS, Windows and drivers
5Recalibrate through Control PanelRecalibrate through search
6Reset the calibrationReset the calibration
7Restore point, then reset the PCRestore point, then reset the system

The Windows 10 version does not spray cleaning solution directly onto the screen either, so the cleaning advice is the same.

Confirm the laptop has a touchscreen

Some ASUS models have no touch panel, so ASUS starts with a check.

  1. Search the Windows search bar for View pen and touch info and open it.
  2. Read the Pen and touch section.

If it says No pen or touch input is available for this display, the laptop does not have a touchscreen.

If the screen seems to respond to touch but the specifications do not list it, ASUS says to ask a local authorized service center to evaluate it.

Clean the screen and remove accessories

Dirt, moisture and add-ons can confuse the touch layer.

  1. Turn the laptop off and check the screen for damage.
  2. Wipe it gently with a soft cloth that is only slightly damp, using plain water if you have no cleaning solution.
  3. Do not spray liquid onto the screen or let it pool.
  4. Let the screen dry completely, then turn the laptop on and test.
  5. Remove any screen protector or accessory near the screen and test again.

Touch the screen only with clean hands or a stylus while testing.

Enable and reinstall the touch driver

A disabled or damaged driver is a common reason for a dead touchscreen.

  1. Search for Device Manager and open it.
  2. Expand Human Interface Devices.
  3. Right-click HID-compliant touch screen and choose Enable device if that option appears.
  4. Right-click HID-compliant touch screen again and choose Uninstall device.
  5. Select Uninstall to confirm.
  6. Select Action, then Scan for hardware changes.
  7. Restart the laptop and test the screen.

If the Enable device option does not show up, the device is already enabled.

If two touch screen entries appear, uninstall the first, then repeat for the second.

The driver reinstalls by itself, and ASUS says this may need an internet connection.

Update the BIOS, Windows and drivers

What to updateHow
BIOSFrom inside Windows, or with ASUS EZ Flash.
WindowsRun Windows Update.
DriversUse System Update in the MyASUS app.

Test the screen again after the updates finish.

Recalibrate the touch display

Calibration teaches Windows which part of the screen each touch belongs to.

  1. Open Control Panel.
  2. Select Hardware and Sound.
  3. Select Calibrate the screen for pen or touch input.
  4. Select Setup, then choose Touch input, or Pen input if you use a stylus.
  5. Follow the on-screen instructions to identify the screen as a touchscreen.
  6. Tap the screen to test it.

On Windows 10 you can skip Control Panel and search for Calibrate the screen for pen or touch input instead.

Reset the touch calibration

If calibrating did not help, or made touch worse, ASUS says to clear the saved calibration.

  1. Open Control Panel, then Hardware and Sound, then Calibrate the screen for pen or touch input.
  2. Select Reset, then OK.
  3. Restart the laptop and test.

Turn on touch right-click

This is optional, but it fixes the complaint that a long press does nothing.

  1. Open Control Panel and select Hardware and Sound.
  2. Select Pen and Touch.
  3. Open the Touch tab, choose Press and hold, then click Settings.
  4. Check Enable press and hold for right-clicking, then click OK.

Stylus users find the same setting on the Pen Options tab.

SettingWhere to find it
Touch calibrationControl Panel, Hardware and Sound, Calibrate the screen for pen or touch input
Touch right-clickControl Panel, Hardware and Sound, Pen and Touch, Touch tab
Touch driverDevice Manager, Human Interface Devices, HID-compliant touch screen
Touch support checkSearch for View pen and touch info

Restore or reset Windows

If the touchscreen failed after a recent change and a restore point exists, ASUS says to restore the system to a time before the problem began.

Our guide on creating a restore point in Windows 11 explains how to make one.

As a last resort, back up your files and reset the laptop to its original configuration.

Our guide on resetting Windows 11 and keeping your files shows how.

Windows touchscreen fixes

If the ASUS steps do not solve it, our general guide on a touchscreen not working in Windows 11 covers more Windows settings.

If you want the opposite, see how to turn off the touchscreen in Windows 11.

When to contact ASUS

If the problem persists, ASUS says to download MyASUS and run System Diagnosis.

ASUS also offers Chat With Us, Contact Us, a service location finder, Online Repair and a warranty status check on its US support site.

ASUS says screenshots and steps may differ depending on your software version and model.

Read the original steps in the ASUS touchscreen and touch panel troubleshooting article.