How To Fix A Heat Pump That’s Not Heating (2026)

A heat pump that is not heating is most often a settings, power, filter or airflow problem you can check yourself in about 15 minutes.

Frost on the outdoor unit and cooler-feeling air can also be normal behavior, so check those before assuming a failure.

Refrigerant, reversing valve and electrical repairs belong to a licensed technician.

Table of Contents

Quick answer

SymptomLikely causeWhat to do
Blows cool airThermostat on Cool or fan set to OnSet Heat and Auto
Nothing runsTripped breaker or switch offCheck breakers and switches
Weak or lukewarm heatDirty filter or blocked outdoor unitReplace filter and clear debris
Thick ice on outdoor unitDefrost problemCall a technician
Cools fine but will not heatPossible stuck reversing valveCall a technician

Check what is normal first

Heat pump air feels cooler than furnace air.

Carrier says heat pump supply air is typically about 85 to 100°F, while a gas furnace delivers roughly 120 to 140°F.

Cooler air on its own is not a fault if the house still reaches the set temperature.

Carrier also notes that older heat pumps may struggle below about 25 to 30°F and need supplemental heat.

Step 1: Check the thermostat

  1. Confirm the mode is set to Heat, not Cool.
  2. Set the fan to Auto. With the fan set to On, the system blows air even when it is not heating.
  3. Look for a Defrost message on the display. If it shows, wait for it to finish.
  4. Raise the set temperature a few degrees above the room reading to call for heat.

If the room temperature and the thermostat setting stay more than 2 to 3°F apart, the thermostat may need recalibrating per its manual.

Step 2: Check power and breakers

Heat pumps use an outdoor unit and an indoor unit, and each usually has its own breaker.

The outdoor breaker is typically 220 or 240 volts.

  • Reset any tripped breaker once.
  • Confirm the outdoor disconnect switch is on.
  • Confirm the power switch at the indoor air handler is on.

If a breaker trips again, stop and call a professional.

Step 3: Replace a dirty air filter

A clogged filter restricts airflow and can cause lukewarm air or shutdowns.

Trane says standard filters should be replaced every 1 to 3 months, depending on filter quality.

Our guide to changing a furnace filter and picking the right size covers finding the correct size.

Step 4: Inspect the outdoor unit

  • Clear leaves, debris and snow from the top and sides, with the power off.
  • Keep at least 24 inches of open space around the unit, or more if your model requires it.
  • Check that the outdoor fan is running.

Frost and ice: normal or not

What you seeMeaning
Light frost, under 1/4 inchNormal. It should clear during defrost, which typically lasts 5 to 10 minutes.
Ice thicker than 1/4 inchNot normal. Call a technician.
Ice that stays after a defrost cycleNot normal. Call a technician.
Defrost happening very oftenNot normal. Call a technician.

For more on this cycle, read what heat pump defrost mode is and when to worry.

Weak airflow from the vents

Weak airflow and rising energy bills can point to leaky ducts.

Carrier says a typical home loses about 20 to 30 percent of its airflow to duct leaks.

You can inspect exposed ducts by hand for loose joints or gaps.

Hidden ducts in walls, attics or crawl spaces need a contractor to test and seal.

Step 5: Reset the system

  1. Turn the thermostat off.
  2. Switch off the indoor and outdoor breakers.
  3. Wait one minute.
  4. Switch the breakers back on and wait a few minutes.
  5. Set the thermostat to Heat.

Emergency heat: use sparingly

If the outdoor unit is not working, Carrier says you can switch to emergency heat temporarily.

Emergency heat uses electric resistance heat, which can raise your electric bill significantly.

Use it only until a technician can look at the outdoor unit.

Thermostat wiring can also play a part, so see what a thermostat C wire is and whether you need one.

When to call a technician

SignWhy it needs a pro
Cools normally but heats poorlyThe reversing valve may be stuck or failed
Hissing near the outdoor unit or a frozen indoor coilPossible refrigerant leak, which needs licensed handling
Breaker keeps trippingElectrical fault
Checks above change nothingNeeds diagnosis

Trane adds that if the heat pump works in cooling but not in heating, the reversing valve may be stuck or failed, and you should expect to need a professional.

Do not open the panels or handle refrigerant lines yourself.

Trane recommends scheduling heat pump maintenance every fall and spring.

If it still does not heat

  • Note any error code shown on the thermostat or inside the unit panel window and give it to the technician.
  • For a ductless system, see our mini split error codes guide.

FAQ

Why does my heat pump blow cold air in winter?

The thermostat may be on Cool or the fan on On, or the unit may be in a defrost cycle.

Can a heat pump heat in very cold weather?

Many can, but Carrier notes that older units may struggle below about 25 to 30°F and need supplemental heat.

Is frost on my heat pump bad?

A light layer under 1/4 inch is normal and should clear in defrost.

Should I use emergency heat?

Only temporarily, because it can raise your electric bill significantly.

How often should I change the filter?

Every 1 to 3 months for standard filters, per Trane.

Sources: Carrier: heat pump not heating, Trane: heat pump not heating.